Milestone in Inner Mongolia: Advanced Prefabricated Piping Systems Deployed for Data Center Liquid Cooling

2026-08-20

On-site installation is progressing steadily at our data center project in Inner Mongolia. Our field engineering team is actively assembling custom prefabricated piping systems designed for high-density liquid cooling infrastructure.

As outdoor modular cooling containers and dry cooler units take shape, precision-engineered piping networks serve as the vital arteries connecting heat dissipation units to computing racks.

Precision Assembly for Outdoor Modular Cooling Infrastructure

Outdoor installation presents unique structural and environmental challenges. To ensure long-term thermal efficiency and structural stability, our pre-engineered pipe spools feature:

  • Heavy-Duty Structural Support Integration: Pipe runs are elevated and secured using galvanized steel framing, preventing thermal expansion stress and vibration during high-capacity cooling operations.

  • Corrosion-Resistant Flange Joints: High-grade flanged connections with multi-bolt alignment allow for quick, secure joining without on-site cutting or welding, minimizing weather-related risks.

  • Flexible Expansion Joints: Stainless steel corrugated flex joints are integrated near equipment inlets to absorb mechanical vibration from pumps and chillers.


微信图片_20260819163932_40_35


A Moment of Inspiration On Site

During a recent shift, a brilliant rainbow spanned across the Inner Mongolia sky directly above our modular piping lines.

Beyond its visual beauty, this moment reflects our team's dedication and optimism. Building mission-critical infrastructure for the AI era requires unwavering attention to detail and rigorous safety protocols—day in and day out, regardless of working conditions.

On-Site Installation vs. Traditional Field Construction

Project MetricTraditional Field-Welded PipingPrefabricated Piping Systems
Site Assembly SpeedExtended (weather dependent)Rapid modular bolt-on connection
Coating IntegrityVulnerable to field dust & moistureShop-applied with precise field touch-ups
Vibration IsolationCustom field alignment requiredPre-engineered with integrated flex joints
System CleanlinessHigh risk of slag/debris in linePre-flushed spools preserve liquid cooling loops

Looking Ahead

With this phase progressing as scheduled, our team remains focused on strict quality checks, torque validation for every flange connection, and final system pressure testing. We look forward to sharing more updates as we bring this high-performance data center liquid cooling system online.